{"product_id":"omron-d4n-4120-roller-lever-safety-limit-switch","title":"Omron D4N-4120 Roller Lever Safety Limit Switch","description":"\u003carticle\u003e\n  \u003ch2\u003eOmron D4N-4120 Roller Lever Safety Limit Switch – 1NC + 1NO, M20, IP67\u003c\/h2\u003e\n\n  \u003cp\u003eThe Omron D4N-4120 is a compact, mechanically operated safety limit switch designed to detect the position or end of travel of moving equipment. When a cam or moving component pushes the roller lever, the switch changes its contact state, providing a signal to a compatible control system.\u003c\/p\u003e\n\n  \u003cp\u003eFeaturing a resin roller lever, snap-action switching and separate normally closed (NC) and normally open (NO) contacts, it is suitable for position monitoring and travel-limit applications where its specifications match the equipment requirements. The NC contact incorporates a certified direct-opening mechanism for use within an appropriately designed safety circuit.\u003c\/p\u003e\n\n  \u003ch3\u003eFeatures and Specifications\u003c\/h3\u003e\n\n  \u003ctable\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eD4N-4120\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eSwitching action\u003c\/th\u003e\n\u003ctd\u003eSnap-action\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eContact configuration\u003c\/th\u003e\n\u003ctd\u003e1 normally closed + 1 normally open\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator\u003c\/th\u003e\n\u003ctd\u003eResin lever with resin roller\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eRoller size\u003c\/th\u003e\n\u003ctd\u003e17.5mm diameter × 6.8mm wide\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eLever radius\u003c\/th\u003e\n\u003ctd\u003e26mm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eCable entry\u003c\/th\u003e\n\u003ctd\u003eSingle M20 entry\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure protection\u003c\/th\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectrical protection\u003c\/th\u003e\n\u003ctd\u003eClass II double insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e−30°C to +70°C, without icing\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eMechanical durability\u003c\/th\u003e\n\u003ctd\u003eMinimum 15 million operations\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum operating frequency\u003c\/th\u003e\n\u003ctd\u003e30 operations per minute\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eCountry of manufacture\u003c\/th\u003e\n\u003ctd\u003eJapan, as marked on the pictured unit\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003ch3\u003eElectrical Ratings\u003c\/h3\u003e\n\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAC-15:\u003c\/strong\u003e 3A at 240V AC.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDC-13:\u003c\/strong\u003e 0.27A at 250V DC.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003cp\u003eThese ratings describe the switch’s contact switching capacity, rather than a required power supply. The switch operates mechanically and does not generate voltage.\u003c\/p\u003e\n\n  \u003ch3\u003eTerminal Identification and Operation\u003c\/h3\u003e\n\n  \u003ctable\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth scope=\"col\"\u003eTerminals\u003c\/th\u003e\n        \u003cth scope=\"col\"\u003eContact Type\u003c\/th\u003e\n        \u003cth scope=\"col\"\u003eLever Released\u003c\/th\u003e\n        \u003cth scope=\"col\"\u003eLever Actuated Past Switching Point\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003e11–12\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003eNormally closed (NC)\u003c\/td\u003e\n        \u003ctd\u003eClosed \/ continuity\u003c\/td\u003e\n        \u003ctd\u003eOpen \/ no continuity\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003e33–34\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003eNormally open (NO)\u003c\/td\u003e\n        \u003ctd\u003eOpen \/ no continuity\u003c\/td\u003e\n        \u003ctd\u003eClosed \/ continuity\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003cp\u003eThe contact pairs are electrically separate and do not share a common terminal. Only the \u003cstrong\u003e11–12 NC contact\u003c\/strong\u003e has the certified direct-opening function. Always identify connections using the terminal markings inside the switch.\u003c\/p\u003e\n\n  \u003ch3\u003eWiring and Installation Instructions\u003c\/h3\u003e\n\n  \u003cp\u003e\u003cstrong\u003eInstallation must be completed by a suitably qualified installer, with mains wiring handled by a licensed electrician.\u003c\/strong\u003e Follow the Omron instructions supplied with the switch and the equipment manufacturer’s wiring diagram.\u003c\/p\u003e\n\n  \u003col\u003e\n    \u003cli\u003e\n      \u003cstrong\u003eIsolate the equipment.\u003c\/strong\u003e\n      Disconnect all relevant power supplies, verify the circuit is de-energised and secure moving equipment before opening the switch.\n    \u003c\/li\u003e\n    \u003cli\u003e\n      \u003cstrong\u003eCheck the controller requirements.\u003c\/strong\u003e\n      Confirm whether the controller requires a normally closed or normally open contact, and identify its designated input terminals.\n    \u003c\/li\u003e\n    \u003cli\u003e\n      \u003cstrong\u003eConnect the appropriate contact pair.\u003c\/strong\u003e\n      For a controller requiring a normally closed, voltage-free limit input, connect its designated input and input-common terminals across \u003cstrong\u003e11–12\u003c\/strong\u003e.\n      For a normally open, voltage-free position input, use \u003cstrong\u003e33–34\u003c\/strong\u003e.\n      These examples apply only to controllers that specify dry-contact inputs. Do not apply an external voltage to a controller input unless its manufacturer explicitly requires it.\n    \u003c\/li\u003e\n    \u003cli\u003e\n      \u003cstrong\u003eFit the cable entry.\u003c\/strong\u003e\n      Use a suitable non-metallic M20 cable gland matched to the cable diameter and required sealing performance. Do not use metal connectors or metal conduits.\n    \u003c\/li\u003e\n    \u003cli\u003e\n      \u003cstrong\u003eTerminate the conductors.\u003c\/strong\u003e\n      The supplied instructions specify \u003cstrong\u003e0.5–0.75mm² (AWG20–18)\u003c\/strong\u003e wire with suitable insulated M3.5 crimp terminals. Keep wiring clear of the moving mechanism and cover seal.\n    \u003c\/li\u003e\n    \u003cli\u003e\n      \u003cstrong\u003eTighten and close.\u003c\/strong\u003e\n      Tighten terminal screws to \u003cstrong\u003e0.6–0.8N·m\u003c\/strong\u003e and the cover screw to \u003cstrong\u003e0.5–0.7N·m\u003c\/strong\u003e. Ensure the cover seal is correctly seated and no wires are trapped.\n    \u003c\/li\u003e\n  \u003c\/ol\u003e\n\n  \u003ch3\u003eTesting and Commissioning\u003c\/h3\u003e\n\n  \u003cp\u003eWith power isolated and the switch disconnected from the controller, check continuity across each contact pair using a multimeter. Operate and release the lever several times and confirm the results match the terminal table.\u003c\/p\u003e\n\n  \u003cp\u003eAfter reconnecting the wiring and closing the enclosure, test the equipment under controlled conditions to verify the intended limit response. Safety applications require validation of the complete safety circuit; an audible click alone does not confirm direct opening.\u003c\/p\u003e\n\n  \u003ch3\u003eApplication and Compatibility Notes\u003c\/h3\u003e\n\n  \u003cp\u003eThe supplied instructions specify \u003cstrong\u003eindoor use\u003c\/strong\u003e, despite the IP67 enclosure rating. Correct cable sealing and cover installation are required to maintain enclosure protection.\u003c\/p\u003e\n\n  \u003cp\u003eBefore ordering, compare the model number, mounting arrangement, actuator travel, contact configuration and electrical ratings with your existing equipment. Final controller connections must follow the equipment manufacturer’s wiring diagram.\u003c\/p\u003e\n\u003c\/article\u003e","brand":"Remote Pro","offers":[{"title":"Default Title","offer_id":62976088146290,"sku":"RP000523","price":50.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0263\/9827\/files\/OMRON-D4n-4120__side-a__top__view-000.jpg?v=1795048532","url":"https:\/\/www.remotepro.com.au\/products\/omron-d4n-4120-roller-lever-safety-limit-switch","provider":"Remote Pro","version":"1.0","type":"link"}