Omron D4N-4120 Roller Lever Safety Limit Switch – 1NC + 1NO, M20, IP67
The Omron D4N-4120 is a compact, mechanically operated safety limit switch designed to detect the position or end of travel of moving equipment. When a cam or moving component pushes the roller lever, the switch changes its contact state, providing a signal to a compatible control system.
Featuring a resin roller lever, snap-action switching and separate normally closed (NC) and normally open (NO) contacts, it is suitable for position monitoring and travel-limit applications where its specifications match the equipment requirements. The NC contact incorporates a certified direct-opening mechanism for use within an appropriately designed safety circuit.
Features and Specifications
| Brand | Omron |
|---|---|
| Model | D4N-4120 |
| Switching action | Snap-action |
| Contact configuration | 1 normally closed + 1 normally open |
| Actuator | Resin lever with resin roller |
| Roller size | 17.5mm diameter × 6.8mm wide |
| Lever radius | 26mm |
| Cable entry | Single M20 entry |
| Enclosure protection | IP67 |
| Electrical protection | Class II double insulation |
| Operating temperature | −30°C to +70°C, without icing |
| Mechanical durability | Minimum 15 million operations |
| Maximum operating frequency | 30 operations per minute |
| Country of manufacture | Japan, as marked on the pictured unit |
Electrical Ratings
- AC-15: 3A at 240V AC.
- DC-13: 0.27A at 250V DC.
These ratings describe the switch’s contact switching capacity, rather than a required power supply. The switch operates mechanically and does not generate voltage.
Terminal Identification and Operation
| Terminals | Contact Type | Lever Released | Lever Actuated Past Switching Point |
|---|---|---|---|
| 11–12 | Normally closed (NC) | Closed / continuity | Open / no continuity |
| 33–34 | Normally open (NO) | Open / no continuity | Closed / continuity |
The contact pairs are electrically separate and do not share a common terminal. Only the 11–12 NC contact has the certified direct-opening function. Always identify connections using the terminal markings inside the switch.
Wiring and Installation Instructions
Installation must be completed by a suitably qualified installer, with mains wiring handled by a licensed electrician. Follow the Omron instructions supplied with the switch and the equipment manufacturer’s wiring diagram.
- Isolate the equipment. Disconnect all relevant power supplies, verify the circuit is de-energised and secure moving equipment before opening the switch.
- Check the controller requirements. Confirm whether the controller requires a normally closed or normally open contact, and identify its designated input terminals.
- Connect the appropriate contact pair. For a controller requiring a normally closed, voltage-free limit input, connect its designated input and input-common terminals across 11–12. For a normally open, voltage-free position input, use 33–34. These examples apply only to controllers that specify dry-contact inputs. Do not apply an external voltage to a controller input unless its manufacturer explicitly requires it.
- Fit the cable entry. Use a suitable non-metallic M20 cable gland matched to the cable diameter and required sealing performance. Do not use metal connectors or metal conduits.
- Terminate the conductors. The supplied instructions specify 0.5–0.75mm² (AWG20–18) wire with suitable insulated M3.5 crimp terminals. Keep wiring clear of the moving mechanism and cover seal.
- Tighten and close. Tighten terminal screws to 0.6–0.8N·m and the cover screw to 0.5–0.7N·m. Ensure the cover seal is correctly seated and no wires are trapped.
Testing and Commissioning
With power isolated and the switch disconnected from the controller, check continuity across each contact pair using a multimeter. Operate and release the lever several times and confirm the results match the terminal table.
After reconnecting the wiring and closing the enclosure, test the equipment under controlled conditions to verify the intended limit response. Safety applications require validation of the complete safety circuit; an audible click alone does not confirm direct opening.
Application and Compatibility Notes
The supplied instructions specify indoor use, despite the IP67 enclosure rating. Correct cable sealing and cover installation are required to maintain enclosure protection.
Before ordering, compare the model number, mounting arrangement, actuator travel, contact configuration and electrical ratings with your existing equipment. Final controller connections must follow the equipment manufacturer’s wiring diagram.